Power specifications, Quickspecs – Compaq ProLiant DL585 G2 User Manual
Page 40

Part number
Part number
Part number
Part number
348114-001
Operational Input Voltage Range
Operational Input Voltage Range
Operational Input Voltage Range
Operational Input Voltage Range
(Vrms)
90 to 264
Frequency Range
Frequency Range
Frequency Range
Frequency Range (Nominal) (Hz)
47 to 63 (50/60)
Nominal Input Voltage
Nominal Input Voltage
Nominal Input Voltage
Nominal Input Voltage (Vrms)
100
100
100
100
115
115
115
115
208
208
208
208
220
220
220
220
230
230
230
230
240
240
240
240
Max Rated Output Wattage Rating
910
910
1300
1300
1300
1300
Nominal Input Current (A rms)
11.9
10.2
7.7
7.3
6.9
6.6
Max Rated Input Wattage Rating (Watts)
1163
1148
1566
1566
1548
1548
Max. Rated VA (Volt-Amp)
1186
1172
1598
1598
1579
1579
Efficiency (%)
80
81
83
83
84
84
Power Factor
0.98
0.98
Leakage Current (mA)
0.43
0.50
0.90
0.96
1.00
1.04
Max. Inrush Current (A peak)
100
100
100
100
100
100
Max. Inrush Current duration (mS)
10
NOTE:
NOTE:
NOTE:
NOTE: – To review typical system power ratings use the Active Answers Power Calculator which is available via the online tool
located at url:
To drill down to calculators:
Click on: "ProLiant Servers"
Click on the Server of interest. Example: DL585 G2
Click on: "Power Calculator" link. (You may need to scroll down to see it)
There are certain Dual-core, lowline, max configurations that are not supported. All highline configurations are supported.
Consult the Power Calculator to determine if your lowline configuration is supported.
Standard Rack Model
Standard Rack Model
Standard Rack Model
Standard Rack Model
Power Cords / Jumper
Power Cords / Jumper
Power Cords / Jumper
Power Cords / Jumper
Cords
Cords
Cords
Cords
Description
Description
Description
Description
IEC320-C14 to IEC320-C19 Jumper Cord
Optional Country Power
Optional Country Power
Optional Country Power
Optional Country Power
Cords and Jumper Cords
Cords and Jumper Cords
Cords and Jumper Cords
Cords and Jumper Cords
Description
Description
Description
Description
Option Kit Part
Option Kit Part
Option Kit Part
Option Kit Part
Number
Number
Number
Number
Nema 5-15P to IEC320-C19
235603-001
Nema 6-20P to IEC320-C19
235604-001
Nema L6-20P to IEC320-C19, 20A, 250V
340653-001
IEC320-C19 to IEC320-C14 Jumper (10A, IEC, 6 ft/2.0m)
313227-B21
IEC320-C19 to IEC320-C14 Jumper (10A, IEC, 8 ft/2.5m)
291034-B21
IEC320-C19 to IEC320-C14 Jumper (10A, IEC, 10 ft/3.0m)
310927-B21
IEC320-C19 to IEC320-C14 Jumper (10A, IEC, 12ft/3.7m)
313228-B21
IEC320-C19 to IEC320-C20 Jumper (16A, IEC, 8ft/2.5m)
295633-B22
QuickSpecs
HP ProLiant DL585 Generation 2 (G2)
HP ProLiant DL585 Generation 2 (G2)
HP ProLiant DL585 Generation 2 (G2)
HP ProLiant DL585 Generation 2 (G2)
Power Specifications
DA - 12575 Canada — Version 37 — May 28, 2008