Output of the weight – Triner Scale 1200g High Precision User Manual
Page 13

User’s Guide | 1200g
11
Output of the Weight
The weight indicated on the scale’s display can be
output to: A) a compatible serial receipt printer, B) a
compatible remote display, or C) a compatible PC.
OUTPUT TO RECEIPT PRINTER
To send the weight information from the CZ 1200 to
a compatible receipt printer (required settings are
based on printer specifications):
1) Connect the scale to the printer using a
standard DB9 null modem cable.
2) Access the Technical Parameters of the
CZ 1200 scale (see the previous section
“Adjusting the Parameters”).
3) Navigate to the P2 Con parameter.
4) Press ENTER. Press MODE to select S
232 or S USb as required, based on the
printer.
5) Press ENTER. Press MODE to navigate
to P Prt.
6) Press ENTER. Press MODE to navigate
to the correct baud rate, based on the
printer. The most common rate is 9600.
7) Press enter. Press MODE to select tP.
8) Press ENTER to accept settings.
9) With P2 Con displaying, press ESC.