Step 1
For optimal performance, it is imperative there is
a level surface prior to installation of new Linear
Shower Pan. Check existing floor to make sure it is
level. If it is not, please correct prior to installation.
Place the Linear Shower pan in desired location
and check to make sure it is level.
Step 2
Once the pan is in the desired location, holding the
pan steady, trace the inner perimeter of the linear
drain cut out. This will mark the location of the
linear drain on the subfloor, making it easier to cut
out in the next step.
Step 3
Using the marked plywood as a guide carefully cut
along your line as accurately as possible. Make
sure to adjust the depth of your saw to the thick-
ness of the subfloor as to not cut through the joists.
Note: If possible, please check or mark location of
existing plumbing and electrical to avoid damag-
ing them.
Step 4
Set the pan into place. Note location of the drain
and make your connections to the waste line.
Install drain in accordance with current plumbing