beautypg.com

Installation guide, Step 17, Step 20 – Trending Accessibility Adjustable fusion shower pan recessed into concrete User Manual

Page 8: Step 18, Step 19

background image

Installation Guide

www.trendingaccessibility.com

[email protected]

8

for adjustable fusion shower pan recessed into concrete

Step 20

Begin the application of the liquid waterproofing

membrane. Paint a layer of liquid waterproofing

over all taped joints. It is easiest to begin with the

walls first and then proceed to the floor area. For

consistant application, use a paint roller to apply

waterproofing to all surfaces. After first coat is dry,

re-coat.

Step 18

Using the provided precut piece of gasket

membrane, slather area where gasket piece

will adhered to the drain area. Place over drain

adapter flange, making sure to cover all screw

holes, and securely press down into flange. Coat

top of gasket piece with liquid waterproofing.

Important: Remember to remove the clamping

ring prior to placing drain gasket.

Gasket Clamp

Drain Adapter Flange

Gasket

Membrane

Step 19

Now attach the clamping ring. Apply solvent

cement to inside of clamping ring. Press firmly into

position and allow the solvent to set.

NOTE: Do not allow the solvent cement to come

into contact with the membrane

Gasket Clamp

Drain Adapter Flange

Gasket Membrane

Step 17

Using the 5” crack isolation tape. Overlap all seams

on either the floors or walls. Overlap the seam where

the Fusion pan and concrete meet.

Make sure the tape

overlaps the seams

equally.