Installation guide, Step 17, Step 20 – Trending Accessibility Adjustable fusion shower pan recessed into concrete User Manual
Page 8: Step 18, Step 19
Installation Guide
www.trendingaccessibility.com
8
for adjustable fusion shower pan recessed into concrete
Step 20
Begin the application of the liquid waterproofing
membrane. Paint a layer of liquid waterproofing
over all taped joints. It is easiest to begin with the
walls first and then proceed to the floor area. For
consistant application, use a paint roller to apply
waterproofing to all surfaces. After first coat is dry,
re-coat.
Step 18
Using the provided precut piece of gasket
membrane, slather area where gasket piece
will adhered to the drain area. Place over drain
adapter flange, making sure to cover all screw
holes, and securely press down into flange. Coat
top of gasket piece with liquid waterproofing.
Important: Remember to remove the clamping
ring prior to placing drain gasket.
Gasket Clamp
Drain Adapter Flange
Gasket
Membrane
Step 19
Now attach the clamping ring. Apply solvent
cement to inside of clamping ring. Press firmly into
position and allow the solvent to set.
NOTE: Do not allow the solvent cement to come
into contact with the membrane
Gasket Clamp
Drain Adapter Flange
Gasket Membrane
Step 17
Using the 5” crack isolation tape. Overlap all seams
on either the floors or walls. Overlap the seam where
the Fusion pan and concrete meet.
Make sure the tape
overlaps the seams
equally.