beautypg.com

Maximum ratings, Operating range, Electrical characteristics – Cypress CY7B9911V User Manual

Page 8

background image

CY7B9911V

3.3V RoboClock+™

Document Number: 38-07408 Rev. *D

Page 8 of 14

Maximum Ratings

Operating outside these boundaries may affect the performance
and life of the device. These user guidelines are not tested.

Storage Temperature ................................. –65°C to +150°C

Ambient Temperature with
Power Applied ............................................ –55°C to +125°C

Supply Voltage to Ground Potential................–0.5V to +7.0V

DC Input Voltage ............................................–0.5V to +7.0V

Output Current into Outputs (LOW)............................. 64 mA

Static Discharge Voltage........................................... > 2001V
(MIL-STD-883, Method 3015)

Latch up Current..................................................... > 200 mA

Operating Range

Range

Ambient Temperature

V

CC

Commercial

0°C to +70°C

3.3V

± 10%

Electrical Characteristics

Over the Operating Range

[5]

Parameter

Description

Test Conditions

CY7B9911V

Unit

Min

Max

V

OH

Output HIGH Voltage

V

CC

= Min, I

OH

= –18 mA

2.4

V

V

OL

Output LOW Voltage

V

CC

= Min, I

OL

= 35 mA

0.45

V

V

IH

Input HIGH Voltage (REF and FB inputs only)

2.0

V

CC

V

V

IL

Input LOW Voltage (REF and FB inputs only)

–0.5

0.8

V

V

IHH

Three Level Input HIGH Voltage (Test, FS,
xFn)

[5]

Min

≤ V

CC

≤ Max

0.87 * V

CC

V

CC

V

V

IMM

Three Level Input MID Voltage (Test, FS,
xFn)

[5]

Min

≤ V

CC

≤ Max

0.47 * V

CC

0.53 * V

CC

V

V

ILL

Three Level Input LOW Voltage (Test, FS,
xFn)

[5]

Min

≤ V

CC

≤ Max

0.0

0.13 * V

CC

V

I

IH

Input HIGH Leakage Current (REF and FB
inputs only)

V

CC

= Max, V

IN

= Max

20

μA

I

IL

Input LOW Leakage Current (REF and FB
inputs only)

V

CC

= Max, V

IN

= 0.4V

–20

μA

I

IHH

Input HIGH Current (Test, FS, xFn)

V

IN

= V

CC

200

μA

I

IMM

Input MID Current (Test, FS, xFn)

V

IN

= V

CC

/2

–50

50

μA

I

ILL

Input LOW Current (Test, FS, xFn)

V

IN

= GND

–200

μA

I

OS

Short Circuit Current

[7]

V

CC

= MAX, V

OUT

= GND (25° only)

–200

mA

I

CCQ

Operating Current Used by Internal Circuitry

V

CCN

= V

CCQ

= Max, All

Input Selects Open

Com’l

95

mA

Mil/Ind

100

I

CCN

Output Buffer Current per Output Pair

[8]

V

CCN

= V

CCQ

= Max,

I

OUT

= 0 mA Input Selects Open, f

MAX

19

mA

PD

Power Dissipation per Output Pair

[9]

V

CCN

= V

CCQ

= Max,

I

OUT

= 0 mA Input Selects Open, f

MAX

104

mW

Notes

5. For more information see Group A subgroup testing information

.

6. These inputs are normally wired to VCC, GND, or left unconnected (actual threshold voltages vary as a percentage of VCC). Internal termination resistors hold

unconnected inputs at VCC/2. If these inputs are switched, the function and timing of the outputs glitch and the PLL may require an additional tLOCK time
before all data sheet limits are achieved.

7. CY7B9911V must be tested one output at a time, output shorted for less than one second, less than 10% duty cycle. Room temperature only.
8. Total output current per output pair is approximated by the following expression that includes device current plus load current:

CY7B9911V: ICCN = [(4 + 0.11F) + [[((835 –3F)/Z) + (.0022FC)]N] x 1.1
Where

F = frequency in MHz
C = capacitive load in pF
Z = line impedance in ohms
N = number of loaded outputs; 0, 1, or 2
FC = F < C

9. Total power dissipation per output pair is approximated by the following expression that includes device power dissipation plus power dissipation due to the

load circuit:
PD = [(22 + 0.61F) + [[(1550 + 2.7F)/Z) + (.0125FC)]N] x 1.1. (See note 8 for variable definition.)

[+] Feedback