6. TROUBLESHOOTING

Symptom

Possible cause

Remedy

Power indicator does not
light even if the power
switch is turned on.

• The AC adapter is not plugged into

a working AC outlet, or is not
plugged in correctly.

• AC adapter plug is not connected to

the charger.

• Make sure the AC adapter is

plugged in to a working AC wall
outlet correctly.

• Connect the plug to the charger's

power input terminal.

Charging indicator (red)
does not light even when
the unit is inserted into the
rechargeable unit
receptacle.

• The batteries used in the unit may

not be dedicated WB-2000
batteries.

• The unit may not be seated

correctly in the rechargeable unit
receptacle.

[WM-5225 and WM-5265]
• The mounting adapter may not be

installed correctly.

• Install the appropriate dedicated

WB-2000 battery in the unit.

• Make sure that the unit is inserted

fully into charger as far as it will go.

• Install the mounting adapter

correctly.

Inserting the unit into the
rechargeable unit
receptacle causes the
charging indicator (red) to
flash.

• The ambient temperature may

exceed the permissible operating
temperature range (0 to 40 ºC, or
32 to 104 ºF), preventing charging.

• Perform charging within the

operating temperature range (0 to
40 ºC, or 32 to 104 ºF).

Full-charge indicator
(green) always lights soon.

• The dedicated WB-2000 battery has

probably reached the end of its life
cycle (usually after about 500
charges and discharges).

• Replace the WB-2000 battery with a

new one.

Full-charge indicator does
not light even 3 hours after
charging has been started
(maximum charging time:
3 hours).

• The power switch of the unit being

charged may be set to ON.

• The battery may be at the end of its

life.

• Set the unit's power switch to OFF.
• Replace the rechargeable battery

with a new one.

Both the charging indicator
(red) and the full-charge
indicator (green) light
alternately.

• The unit may have been installed

with a non-WB-2000 battery.

• There may be foreign objects (such

as metals) in the rechargeable unit
receptacle.

• The battery may be at the end of its

life.

• The power switch of the unit being

charged may be set to ON.

• Use a dedicated WB-2000 battery

in the unit.

• Remove such foreign objects.

• Replace the WB-2000 battery with a

new one.

• Set the unit's power switch to OFF.