Vermont Casting VC0620P User Manual
Page 6
Valve
Orifice
Dual Burner
Fuel-Control Valve
Fuel Supply
Hose
Type 1 Fuel
Regulator
The L.P. Fuel Supply System
(the fuel regulator and hose)
4. The pressure regulator and hose
assembly provided is factory set at an outlet
pressure of 11 inches water column (.4 lb.
per sq. Inch).
L.P. Cylinders can be obtained at the store
where you purchased your grill or from an
authorized L.P. gas dealer.
Any L.P. gas-supply cylinder used with this
grill must be approximately 12 inches
diameter and 18 inches high.
L.P. GAS SUPPLY CYLINDER
L.P. GAS CYLINDER SPECIFICATIONS
The maximum
fuel capacity must be 20 pounds of propane.
Full-cylinder weight should be approximately
38 pounds (43.7 lbs. Nominal water
capacity).
The L.P. cylinder must have a shut-off valve
FUEL REGULATOR AND HOSE
The fuel regulator supplied is equipped with
a Type 1 coupling nut. Do not attempt to
connect to any other L.P. cylinder not
equipped with a mating Type 1 cylinder
valve. This grill is not to be used with any
other cylinder connection device.
The fuel regulator and hose assembly with
the Type 1 fitting supplied must be used with
the appliance. Do not use a hose and
regulator assembly other than the one
supplied with the grill or a manufacturer’s
replacement fuel pressure regulator
assembly.
The Type 1 connection system has the
following features:
1. The system will not allow gas to flow until
a positive connection has been made.
2. The system has a thermal element that
will shut off the flow of gas between 240°F
and 300°F.
3. The system has a flow-limiting device
which, when activated, will limit the flow of
gas to 10 cubic feet per hour.
6
Cylinder Control
Valve
The L.P. Fuel Supply System
(L.P. gas cylinder)
L.P. Gas
Cylinder
Any attempt to adjust the
regulator is dangerous and could create a
situation causing personal injury or property
damage. Consult your L.P. gas dealer if you
think the regulator is not working properly.
WARNING:
NOTE:
Some L.P.
grill models
DO NOT
include an
L.P. gas
cylinder