Page 33 of 33 – Toa 9000M2 Series Ver.200A User Manual
Page 33

Page 33 of 33
Input ch2 Hpf 31.5Hz
A2H, 04H, 00H, 01H, 00H, 03H
A2H, 04H, 00H, 01H, 00H, 03H
Output ch1 Lpf 6.3kHz
A2H, 04H, 01H, 00H, 01H, 02H
A2H, 04H, 01H, 00H, 01H, 02H
Command Controller
9000M2
Response
Input sensitivity setting
Input ch1 Insense -24dB
ACH, 02H, 00H, 02H
ACH, 02H, 00H, 02H
Speaker preset setting
Output ch2 SpPreset F-122
ADH, 02H, 01H, 01H
ADH, 02H, 01H, 01H
Phantom power setting
Input ch3 Phantom ON
87H, 02H, 02H, 01H
87H, 02H, 02H, 01H
Paging Event Preset Recall
Paging No1 Activates
F2H,02H,00H,01
F2H,02H,00H,01
Channel name recall
Input ch1 Name “INPUT1”
F0H, 03H, 40H, 00H, 00H
C0H, 09H, 00H, 00H,
49H, 4EH, 50H,
55H, 54H, 31H, 00H
ANC ADJUST
Reference Level Of Ch1 to
–9dB
AEH,02H,00H,01H C1H,01H,00H
ANC Get Reference
Acquiring reference level of
Ch1
F3H,01H,00h C2H,01H,32H(0dB)