Input sensitivity table – Toa 9000M2 Series Ver.200A User Manual
Page 21

Page 21 of 33
5.10. Input Sensitivity Setting
Performs input sensitivity setting of Input channel. 9000M2 Series Amplifier responds with
the same data as that received. Input sensitivity setting is enabled only for the channel on
which the D-001T or AN-001T is used.
Note: Command cannot be received during power off.
ACH, 02H,
00H - 07H (Input channel 1 - 8)
INPUT SENSITIVITY TABLE
Value
Value
HEX
DEC
Sense
(dB)
HEX
DEC
Sense
(dB)
00H 0
-10 05H 5
-42
01H 1
-18 06H 6
-48
02H 2
-24 07H 7
-54
03H 3
-30 08H 8
-60
04H 4
-36
Example: Setting the input sensitivity of Input Channel 5 to –24 dB.
ACH, 02H, 04H, 02H