Toa FS-7000 SERIES Manual User Manual
Page 15

15
5.9. FS-7000RM Remote Microphone
The FS-7000RM Remote Microphone is used solely for general-purpose public address applications in FS-
7000 Series Voice Evacuation Systems. It enables broadcasting to up to 10 individual zones, as well as all-
zone calls. One FS-7000RF panel is required in order to connect the FS-7000RM to the system. Up to 4 FS-
7000RM units can be connected. Pressing the FS-7000RM's chime key causes the FS-7000CP's built-in 4-
tone chime to sound. Connection of 4 FS-7010RMs enables broadcasts to 50 individual zones as well as all-
zone calls (expandable by 10 lines per FS-7010RM). Further, up to 20 broadcast zone groups can be created
by connecting the FS-7000RF to an FS-7000GM Group Matrix Panel.
Tip
Connection of 6 FS-7010RM Remote Microphone Extension units enables broadcasting to 50 individual zones
and 20 zone groups, as well as all-zone calls.
[Top]
13
2
3
4
7
1
6
5
8
12
11
9
10
1. Power Indicator
Lights when power is supplied and the
FS-7000RM is ready for operation.
2. Fault Indicator
Lights when any failure is detected in
communications with the FS-7000RF or when any
failure occurs on the FS-7000RM itself.
(See page 30.)
3. All-Zone Call Indicator
Remains lit while an all-zone call is broadcast from
the FS-7000RM. (Lights only when calls are made
from this FS-7000RM.)
4. All-Zone Call Key
Selects all broadcast zones simultaneously.
5. Chime Key
Sounds a 4-tone chime built inside the FS-
7000CP.
6. Broadcast Reset Key
Resets broadcast zones selected via the All-Zone
Call key (4) or Zone Selector keys (11),
terminating broadcasts from the FS-7000RM.
7. Busy Indicator
Lights green when a broadcast is made from this
FS-7000RM, and lights orange when a broadcast
is made from other equipment.
8. Talk Key Indicator
Lights when a microphone announcement is made
using the Talk key (12).
9. Zone Identification Card
Write the names of the broadcast zones on this
card.
10. Zone Selection Indicators
Light when the corresponding Zone Selector
keys (11) are pressed. (Light only when the FS-
7000RM's keys are used.)
11. Zone Selector Keys
Select broadcast zones. Connection of the FS-
7000RF to the FS-7000GM permits simultaneous
selection of multiple broadcast zones.
12. Talk Key
Microphone announcements can be made only
while this key is pressed.
Tip
Key operation can be changed to allow
microphone announcements to alternate
between ON and OFF each time this key is
pressed. (Refer to the separate Installation
Manual.)
13. Microphone