beautypg.com

ThermoWorks SPLASH-PROOF SUPER-FAST THERMAPEN User Manual

Page 3

background image

http://www.thermoworks.com/software/bpcalc_solo.html to quickly find that temperature

for your zip code.

Instructions to use the Trim Adjust to tune your Thermapen calibration are found at the web

address shown above. You should not need to do this under normal use. A complete factory

re-calibration, including a certificate, is also available from ThermoWorks for a fee.

Batteries

Each unit includes two pre-installed CR2032 (3V) coin cell batteries located inside the sealed

battery compartment. An illuminated battery symbol indicates that the battery should be

replaced soon. The instrument will continue to measure accurately, but it is recommended to

replace the batteries immediately. Once the battery is too low to display readings, the display

will be replaced with ‘Flat’ then ‘Bat’ and then shut down. To continue using the instrument,

replace the batteries.

Replacing the Batteries

The batteries are pre-installed on your new Thermapen and

should last up to 1,500 hours. Should you need to replace the

batteries, remove the battery cover with a coin (a U.S. quarter

works best). The battery cover may be tight in order to main-

tain the Thermapen’s splash

resistance. Using firm but even

pressure, rotate the battery cover

only to the open position. Lift the

cover from the hole with a finger-

nail. Place both batteries with the

positive side up making sure that

the clip snaps over the batteries

to hold them in place. Replace the

battery cover.

Cleaning and Maintenance

To avoid potential bacteria growth and cross-contamination, wipe the probe after each use

and regularly clean the entire Thermapen body. Oils and grease should be wiped off the

body and the rotating hub. We recommend sanitizing wipes or a damp paper towel with an

anti-microbial cleaning solution. DO NOT IMMERSE THE THERMAPEN. The built-in seals will

protect the Thermapen from incidental moisture but due to the folding probe, the Thermapen

should not be submerged. Protect the plastic body from high temperatures. DO NOT LEAVE

THE THERMAPEN IN AN OVEN OR ON A HOT SURFACE.

Error Messages

•‘Lo’ is displayed if measurements are being made below the instrument range.

•‘Hi’ is displayed if measurements are being made above the instrument range.

•‘Err’ is displayed if the probe develops a fault. Call for details.

For all other error messages, contact ThermoWorks’ Technical Support at 1-800-393-6434

or [email protected].

What is Biomaster?

Biomaster is a silver based antimicrobial additive incorporated into the Thermapen’s plastic

parts during manufacture. Biomaster helps reduce the growth of unwanted microbes on the

Thermapen’s surface that may cause degradation, discoloration or malodors.

The built in Biomaster protection works in conjunction with regular cleaning and sterilizing of

your Thermapen. The probe is not treated and should still be wiped after each use.

What is NSF Certification?

The NSF Mark indicates that the design, materials, production process and quality controls

used in the production of the Super-Fast Thermapen have been verified and certified for food

safety by NSF International, an independent standards organization.

Backlight Function (Backlit Thermapen only)

When the Thermapen is on, a new display sensor continuously monitors ambient light

levels. As it gets darker, the intelligent backlight comes on automatically so you can read the

CR2032

3V

+

1 2

3 4

ON

CR2032

3V

+

1

2

3

4

ON

O

PE

N

Rotate to open

Lift cover off

Do not force

Open

CR2032 (x2)

Do not force

past here.

Battery Cover

Battery clip