1. INSTALL SPACERS ON STEERING FLOWMETER SENSOR
(Non-ILS only)
On non-ILS machines, there will be hydraulic flowmeter. The two spacers
(G)
will be installed on the
flowmeter sensor. To gain access to the flowmeter sensor the flowmeter may need to be partially removed
(depends upon tractor model). First remove the cover from the air cleaner. Disconnect the steel line from
the flowmeter and remove the two bolts mounting the flowmeter. Then the flowmeter may be slid out and
rotated to gain access to its sensor. Using a 4mm hex wrench remove the two screws holding the sensor.
Then use screws
(H)
to install the spacers
(G)
under the sensor as shown. Slide the flowmeter back into its
mounting location and reinstall the mounting bolts. Then reconnect the steel line to the flowmeter.
Figure 1-3: Install Spacers On Steering Flowmeter Sensor
Flowmeter
remove Bolts
disconnect
sensor