beautypg.com

Fieldpilot – TeeJet FieldPilot Install Case MX Magnum w/Factory Valve User Manual

Page 10

background image

www.teejet.com

10

FieldPilot

®

4. INSTALL VALVE CONTROL CABLE

Locate the factory installed valve. There should be one or two cables already plugged into the valve

connectors. Disconnect them and install the dust caps supplied with cable

(D)

, and then connect cable

(D)

to the factory installed valve. Some factory valves will not require the use of both connectors.
Figure 1-5: Install Valve Control Cable

5. SPECIfIC CONSOLE SETTINgS

The target lock to lock time is

5 seconds

which is accomplished by adjusting the Maximum Duty Cycle

setting in the Matrix console.
The Valve Frequency is

110 Hz

Adjust as needed the other FieldPilot settings in the Matrix console to obtain the best performance.

4-position

Connector

2-position

Connector

Factory Valve