Fieldpilot – TeeJet FieldPilot Install Case MX Magnum w/Factory Valve User Manual
Page 10

www.teejet.com
10
FieldPilot
®
4. INSTALL VALVE CONTROL CABLE
Locate the factory installed valve. There should be one or two cables already plugged into the valve
connectors. Disconnect them and install the dust caps supplied with cable
(D)
, and then connect cable
(D)
to the factory installed valve. Some factory valves will not require the use of both connectors.
Figure 1-5: Install Valve Control Cable
5. SPECIfIC CONSOLE SETTINgS
The target lock to lock time is
5 seconds
which is accomplished by adjusting the Maximum Duty Cycle
setting in the Matrix console.
The Valve Frequency is
110 Hz
Adjust as needed the other FieldPilot settings in the Matrix console to obtain the best performance.
4-position
Connector
2-position
Connector
Factory Valve
Factory Valve