beautypg.com

How to mount the override sensor, Using an electrical signal for override sensor – TeeJet LH 1200S User Manual

Page 5

background image

LH A

GRO

5

HOW TO MOUNT THE OVERRIDE SENSOR

Example of where to place the override sensor


Note:
If you wish the override sensor can be mounted on the PTO handle or other
simular handles. This is possible as long as there is at least 50 mm movement.

USING AN ELECTRICAL SIGNAL FOR OVERRIDE SENSOR

The override sensor can be replaced with an electrical signal from other sources,
the tractors electronic hydraulics system (lift/PTO, etc, etc). An electrical signal
from a fertiliser spreader, sprayer or similar can also be used.
Note: A ground signal (0V) is nesseccary to override the area counter!
Meaning that a switch that sends a ground signal in the "off" position can be used
(a 12 V signal in the "on" position does not matter)
Importent: Such a signal as mentioned above may only be connected to the
blue terminal on the override entrance in the junction box or pin 7 in the pull away
plug.