Oxygen related information displayed by the dive computer is also designed to ensure

all warnings and displays in the appropriate phases of a dive. E.g. the following informa-

tion will be shown before and during a dive, when the computer is set in Nitrox mode:

• the selected O

2

%

• the color-coded OLF% bar graph for either CNS% or OTU%

• audible alarms are given and the OLF bar graph starts to blink when the 80% and

100% limits are exceeded

• the blinking of the bar graph stops, when the PO

2

is below 0.5 bar

• audible alarms are given and the actual PO

2

value blinks when it exceeds the

preset limit

• in dive planning the maximum depth according to the O

2

% and maximum PO

2

selected.

6.4. TECHNICAL SPECIFICATION

Dimensions and weight:

• Diameter: 61 mm [2.4in].

• Thickness: 28 mm [1.1in].

• Weight: 68g [2.4 oz].

Depth Gauge:

• Temperature compensated pressure sensor.

• Calibrated complying with EN 13319, in fresh water the readings are about 3%

smaller.

• Maximum depth of operation: 80 m [262 ft] (complying with EN 13319).