I N S T R U C T I O N M A N U A L • M O D E L S 1 0 9 9 / 1 0 9 6

17

F I N E A D J U S T M E N T S

PRESSURE SWITCH ADJUSTMENT

For systems mounted in the normal vertical position with downward travel, no

adjustment should be necessary. The minimum trigger pressure is factory set

at 4-7 psig.

However, if the minimum trigger pressure requires recalibration or re-

adjustment, observe the following procedure:

1. Maintain air pressure and unplug the power supply from the electrical

source.

2. Remove the four screws holding the five-sided cover.

3. Loosen the jam nut holding the 8-32 cap screw in place.

4. Rotate the cap screw counter-clockwise (up) until the Pressure Switch

closes.

5. Next rotate the cap screw clockwise (down) until the Pressure Switch

opens.

6. Rotate cap screw clockwise (down) one turn past the Pressure Switch

open position.

7. Tighten the jam nut to lock cap screw in position.

8. Replace the cover and four screws.

9. Plug the power supply into the electrical source.

10. Cycle the welder.

The press is now set to trigger at the minimum trigger pressure of 4-7 psig.

A press actuating in an upward or horizontal direction should be set to trigger

at a minimum of 8-10 psig. Lower values may affect trigger performance

where false triggering may be observed.