A. Maximum operating temperature for most Solberg inlet air filter products is
220°F / 105°C. Temperatures in excess of this could cause damage to
elements, media and elastomers. High temperature products are
available.
B. Direction of flow is typically from the outside of the element to the inside of
the element. Most products have arrows indicating direction of flow on the
inlet and outlet ports.
C. Ensure that pipe connections are adequately sealed so the potential for
leaks is reduced to a minimum.
2. Disconnecting Canister Base from Canister Top.
A. Remove V-band by loosening nut or T-handle and releasing. Remove
housing base and O-ring slowly.
Figure C.2.1: V-Band.
Figure C.2.2: Canister base removal.
Figure C.2.3: Canister base and O-ring
free from housing.