Section D
MAINTENANCE RECOMMENDATIONS
1. Pressure drop readings are recommended to have an effective air filter.
Always document initial pressure drop during start-up when element is clean.
Replacement cartridge is needed when
system experiences 10” to 15” / 250-
380mm H
2
O above drop above the initial reading. Refer to page 4 for initial
values.
2. Always check replacement cartridge gaskets to insure they are adhered
uniformly along the end caps during handling. If not, contact Solberg
Manufacturing, Inc. immediately. Do not modify or change from Solberg
specified parts!
3. Always check inlets/outlets, element base and its components when replacing
element to insure cleanliness. Wipe clean if necessary.
4. Operate only when a proper seal exists.
5. Never operate without absolute assurance that V-band is secured correctly
along entire diameter of canisters. Check along V-band for wear. Replace if
any distortion occurs due to handling and usage.