beautypg.com

Solberg SMConfigurationB(Pg.3-10,11) User Manual

Page 5

background image



Solberg Manufacturing, Inc., 1151 Ardmore Itasca, IL 60143 USA

Ph: 630.773.1363 Fax: 630.773.0727 Email: [email protected] Web: www.solbergmfg.com

Page 5

Rule of Thumb #1: Always begin with the filter cartridge requirements when
sizing a filter. Once the appropriate element has been selected, move on to the
housing requirements.

Rule of Thumb #2: Always ask or specify a filter based on a micron rating with
filtration efficiencies
. As an example, stating a requirement for a 1-micron filter
is misleading because no efficiency rating has been specified. A 1-micron filter at
95% efficiency may be less efficient than a 5-micron filter at 99% efficiency. For
proper air system performance in light and industrial duty environments, a filter
with a minimum of 99% filtration efficiency at 5 microns is required.

Rule of Thumb #3:
Size your filter correctly by understanding the impact air
velocity through a media has on efficiency and pressure drop. Maintain the
suggested Air-to-Media ratios listed below based on the external environment
listings and Filtration efficiency needs.


Filtration Efficiency
Requirements
(99%+ efficiency)

Environmental
Conditions

Air to Media Ratio

Industrial Grade 2-micron
Paper

Industrial Duty (clean,
office/warehouse-like)

30 CFM

/

ft

2

(51m

3

/h)

/

cm

2

Severe Duty (workshop,
factory-like)

15 CFM

/

ft

2

(25.5m

3

/h)

/

cm

2

Extreme Duty (Foundry,
Construction-like)

10 CFM

/

ft

2

(17m

3

/h)

/

cm

2

Industrial Grade 5-micron
Polyester

Industrial Duty (clean,
office/warehouse-like)

50 CFM

/

ft

2

(85m

3

/h)

/

cm

2

Severe Duty (workshop,
factory-like)

40 CFM

/

ft

2

(68m

3

/h)

/

cm

2

Extreme Duty (Foundry,
Construction-like)

25 CFM

/

ft

2

(42.5m

3

/h)

/

cm

2

Industrial Grade 1-micron
Polyester

Severe Duty (Foundry,
Construction-like)

10 CFM

/

ft

2

(17m

3

/h)

/

cm

2

Industrial Grade 0.3-micron
HEPA Glass @ 99.97%
Efficiency

Industrial Duty (Pre-filtered
Applications)

10 CFM

/

ft

2

(17m

3

/h)

/

cm

2

Severe Duty (workshop,
factory-like)

7 CFM

/

ft

2

(12m

3

/h)

/

cm

2

Extreme Duty (Foundry,
Construction-like)

5 CFM

/

ft

2

(8.5m

3

/h)

/

cm

2

Table 2