beautypg.com

Solberg SMConfigurationB(Pg.3-10,11) User Manual

Page 4

background image



Solberg Manufacturing, Inc., 1151 Ardmore Itasca, IL 60143 USA

Ph: 630.773.1363 Fax: 630.773.0727 Email: [email protected] Web: www.solbergmfg.com

Page 4

No.

Filter Model

Number

Replacement

Element

Initial Delta P

Readings

1

2

3

4

5

Table 1


The model number designates the filter type, the original element configuration
and housing connection size. For example, the following part number identifies
the filter as being an

‘SM2’ design filter with a 19 element including prefilter and

2” MPT connection:

SM2-19P-200

Filter Type:

SM1.5, SM2, SM3,

SM4 and SM6


Element Type:

Size, Material,

Prefilter, Micron

Rating


Connection
Size and Type



2. Filtration Rules of Thumb

General: For peak output performance from a compressor, blower, vacuum
pump, engine, or any other machine that consumes air, one must have clean,
unrestricted air. Proper filtration can help stabilize the working environment within
rotating equipment even when the external conditions may be quite severe. A
critical component in creating the right working conditions is filter sizing. With the
properly sized filter, equipment will run smoothly over its entire expected
operating life.

A major factor in filtration and filter sizing is air velocity through the filter media.
Generally, the slower the velocity of air through a media the higher the filter
efficiency and, conversely, the lower the pressure drop. Therefore, the primary
goal in filter sizing is to optimize the velocity of air through the media (sometimes
called face velocity).