beautypg.com

Warning – Solberg SMConfigurationB(Pg.3-10,11) User Manual

Page 15

background image



Solberg Manufacturing, Inc., 1151 Ardmore Itasca, IL 60143 USA

Ph: 630.773.1363 Fax: 630.773.0727 Email: [email protected] Web: www.solbergmfg.com

Page 15

*WARNING*

Failure to seat the element properly may
result in contaminant by-pass resulting in
damage to equipment.

2. Check element top plate or cover to make sure it is seated

properly on element.

3. Check housing cover that it is installed correctly onto housing.

4. Be sure all fasteners and hardware have been tightened.

*WARNING*

If the air flow is reversed through a Solberg
filter unit, be sure to check the element and
housing internals for damage. Failure to do
so may result in damage to equipment.

Section D

MAINTENANCE RECOMMENDATIONS

1. Pressure drop readings are recommended to have an effective air filter.

Always document initial pressure drop during start-up when element is clean.
Replacement cartridge is needed when

system experiences 10” to 15” / 250-

380mm H

2

O above drop above the initial reading. Refer to page 4 for initial

values.

2. Always check inlets/outlets, element base and its components when replacing

element to insure cleanliness. Wipe clean if necessary.

3. Operate only when a proper seal exists.