Slant fin corp – Slant/Fin CHS-399 User Manual
Page 23

CHS Series
Controller and Display
│
Slant Fin Corp.
21
Table 2-13 System Identification & Access Parameters
Parameter
Description
Factory Settings
Boiler name
*
Name describing the specific boiler. Limited to 20 characters.
e.g.: 110MBH
OEM ID
Name identifying factory configuration settings; field is read only.
N/A
MB1 Modbus
address *
Modbus communication address used by the display to identify the attached
controller. No need to change this setting. Range: 1 – 8.
1
MB2 Modbus
address *
Unique controller I.D. needed when multiple boilers are connected together in a
Lead Lag cascade configuration. Each boiler in a Lead Lag cascade
configuration must have a unique setting. Range: 1 – 8.
1
Modbus address
Displays the “MB1 Modbus address” setting – do not adjust this setting.
1
Modbus port used Identifies the Modbus port used by the display to controller; field is read only.
MB1
Product ID
Controller type identification; field is read only.
Residential
Product family
Hydronic boiler
OS number
Controller model identification; field is read only.
R7910B1015
Model name
Software version
Controller software version identification; field is read only.
N/A
Date code
Controller date code; field is read only.
N/A
Application
revision
Controller application revision; field is read only.
N/A
Safety
revision
Controller safety revision; field is read only.
N/A
* = Password protected