7.1 Troubleshooting Guide
Malfunction
Cause
Correction
Feed
No round fed into
the chamber
Magazine not
properly inserted
or magazine is
deformed or dirty
Insert magazine
properly or change
magazine
Slide does not close
easily or completely
Pistol or cartridge
is fouled (dirty) or
pistol is too heavily
lubricated
Clean and lubricate
pistol and/or replace
the ammunition
Incorrect ammunition
Replace ammunition
Pistol requires service
Return to SIG SAUER
Extraction/Ejection
After firing, the case
stays in the chamber
or is jammed in the
ejection port
Insufficient recoil due
to dirt
Clean and lubricate
the pistol
Light hold or limp wrist
Solid grip, rigid hold
Low-powered
ammunition
Change ammunition
Pistol requires service
Return to SIG SAUER
Ignition
Hammer drops but
round does not fire
Firing pin obstructed
Inspect, clean and
lubricate the pistol
Faulty ammunition
Manually cycle in
next round
Pistol requires service
Return to SIG SAUER