SeaLand 8911RV SeaLand toilets User Manual
Page 4
![background image](/manuals/710712/4/background.png)
® Registered; ™ Trademark of Dometic Corporation
© Dometic Corporation
600346694 01 12/11
SeaLand MasterFlush Toilets
RV Installation Appendix
CONVERSION TABLE
Wire – AWG to mm
2
Feet to Meters
AWG
14
12
10
Ft
10
15
20
30
50
mm
2
2.5
4.0
6.0
M
3.1
4.6
6.1
9.2
15.2
Wire size per length of run*
0-15 ft.
16-30 ft.
31-50 ft.
12 volts DC
#14
#12
#10
* Distance from circuit breaker to electronic control module.
WIRE SIZING CHART
When installing a SeaLand macerator toilet in a recreation vehicle, please use the following wiring
information. Refer to MasterFlush toilet parts list for complete macerator toilet wiring diagram.
Installation notes
• Each toilet must have its own circuit breaker or fuse.
• Wire sizes must be appropriate for the installation. All other installation factors must be in
accordance with ISO electrical standards.
• Always use stranded copper wire (preferably tinned).
• Always use crimp-type wire connections. Do not use wire nuts (they corrode).
Warning!
Hazard of Shock or Fire: Always use recommended fuse, circuit breaker and wire size.
Failure to do so can cause the loss of property and life.
Wiring / Electrical Connections