40kmc / 40kmq, Room controller” wired control – Carrier 40KMC------301 User Manual
Page 7
40KMC------310/ 40KMQ------310
GB - 6
Power up
All segments of the LCD should be energized for five seconds.
The mode, fan, louver, desired temperature and configuration
information should be read from the EEPROM.
If the EEPROM values are not valid, the following should be used
as defaults.
Operating Mode
= AUTO
Fan Speed
= AUTO
Desired Temperature
= 72°F
°F o °C
= F
Louver
= AUTO
Room Thermistor Override
= OFF
Cooling only vs Heat/Cool Remote = Heat/Cool
When switched on, the control display appears.
Setting mode operation
“
MODE
” button
Pressing the “
MODE
” button will cause the mode to change.
The “
MODE
” button must be released and then pressed again in
order to change to the next mode.
The active mode will always be lit in normal operation.
Available modes to select are:
Heat/Cool Remote:
OFF,
COOL, DRY,
FAN ONLY,
AUTO,
HEAT
Cooling Only Remote:
OFF,
COOL, DRY and
FAN ONLY
When the “
MODE
” button is not pressed for 15 seconds, the next
press will always switch the mode to OFF.
OFF Mode:
ICONS Energized:
• OFF Mode
• Room Temperature if configured for Room Thermistor Override,
otherwise nothing
Buttons available:
• “
MODE
” button
Example of normal operation
AUTO, HEAT, COOL and DRY Modes:
ICONS Energized:
• Operation Mode ICON.
• Room Temperature if configured for Room Thermistor Override
(operated by Room Controller), otherwise user selected
temperature with the “
SET
TEMP
” Icon.
• FAN/LOUVER Icon with the user selected Fan and Louver
settings.
Buttons available:
• All Buttons are available.
AUTO Automatic operation
NOTE:
The compressor and electric heater must be off for at least 30
Minutes, this time being necessary to pass from Heating to
Cooling, or Cooling to Heating.
This will prevent the system from switching between Heating
and Cooling continuously.
COOL Cooling operation
DRY
Drying operation.
HEAT Heating operation.
“Room controller” wired control