Filter cleaning – Santec 7093KT-TM User Manual
Page 8

0 8
7093KL, KR, KT _ _
DURING THE INSTALLATION OR THROUGH THE YEARS OF USE, DEBRIS AND
IMPURITIES MAY CLOG THE FILTERS IN THE BOTH INLETS, CAUSING THE
WATER TO BE RESTRICTED OR DECREASED CONSIDERABLY.
Filter Cleaning
M a i n t e n a n c e
Shut off the water supply.
Remove the dial cap, screw, and dial.
Remove
remaining
assembly
by
carefully applying a plumber’s wrench
to the outside of the sleeve and turn
counter-clockwise.
Remove nut from sleeve and then
remove the plates from the wall.
H
O
T
Check valve
Check valve shut-off
Flush the debris with water. If necessar y, soak in a 50/50 mix of
white vinegar/water until all dirt is dissolved.
Oil the O-rings with vegetable oil and wipe the housing with a wet
cloth before reassembling.
Reinstall the valves.
valve shut off mechanism is fully open (Turn the mechanism