Sandia Aerospace SAC 7-35 User Manual
Page 30
29
4.3.7
Fuel Flow Configuration and K-factor
Parameter Descriptions Con’t
Parameter
Description
Allowed Settings
d. Fuel Start-up delay
Delay Fuel Flow Calculation
(0-12 for 0-60 second delay)
e.Fuel Input
Engine count
0 ,1,2
f.
Fuel Density
0 = 100LL
1 = Jet B
2 = Jet 1A
3 = JetA
or enter #
k.
Fuel Tranducer K-Factors (L&R)
500-130000
4.3.8
List Inputs
This confiruration menu selection lists the
current Altitude. Airpseed, Outside Air Tem-
perature and Baro Setting. The list is in the
form:
Trimmed inputs>>Alt=1234 IAS=321
Baro=29.92 OAT=15.12
The alt is in feet, IAS knots, Baro InHg and
OAT in Deg C
Parameter
Description
Allowed Settings
l. List Inputs
N/A
4.3.9
ARINC Mode
Parameter
Description
Allowed Settings
Note: The ARINC output select is available only in-01 units. In
-01 units the ARINC 429 output can be disabled. The output can
also be configured for Airdata only, ADS-B only or both
m. Mode Select
Select the ARINC output mode
0. ARINC 429 Output Disable
1. ARINC 429 Output Airdata Only
2. ARINC 429 Output ADS-B only
3. ARINC 429 Output ADS-B and Airdata
0-3