Sandia Aerospace SAC 7-35 User Manual
Page 15
Section 3 Installation Procedures
3.1
GENERAL
The SAC 7-35 is supplied with a mounting tray and crimp type mating connectors. It is
important that the proper crimping tools and techniques be observed in attaching wires to the
mating connectors. Failure to do so could result in a failure in the connection and cause inter-
mittent or non operation of the SAC 7-35.
3.2
EQUIPMENT REQUIRED
3.2.1 Supplied
SAC 7-35 System
705548-XX
Includes: SAC 7-35 Airdata Computer
305548-XX
SAC 7-35 Installation Manual
305586-00
SAC 7-35 Installation Kit, Electrical
305588-00
15 Pin Connector Hood
305208
2 each 25 Pin Connector Hoods
305437
25 Pin Female Connector w/Crimp Pins
305583
25 Pin Connector w/Crimp Sockets
305720
15 Pin Male Connector w/Crimp Pins
305721
SAC 7-35 Installation Kit, Mechanical
305589-00
Mounting Tray
305557
Knurled Hold-down Nut
305558
STP 78 OAT Probe
305561-91
OAT Probe Installation Kit
305595-00
Mounting Nut
305560-03
Mounting Lock Washer
305050-10
Fiber Shoulder Washer
305587-03
Flat Fiber Mounting Washer
305581-04
9 pin RS 232 to 6 pin DIN adapter cable
305580
3.2.2 Required But Not Supplied
Number 6-32 Mounting Screws, 3 or 4 depending on your selected mounting option.
Static Port Fitting
Pitot Port fitting
3.3
MOUNTING TRAY INSTALLATION
The mounting tray is mounted to the airframe using either three or four number 6-32 screws.
The mounting hole pattern for the SAC 7-35 mounting tray contains five holes. For new instal-
lations, it is recommended that the four corner holes be used to mount the SAC 7-35 tray. The
fifth hole has been added to facilitate upgrades from some manufactures encoders. Refer to the
SAC 7-35 tray dimensions in Figure 3-1 to determine if the hole pattern of the removed system
match the hole pattern of the SAC 7-35 mounting tray.
14