beautypg.com

Potter EVD-2 User Manual

Page 5

background image

5

EVD-2 • 5401042 • REV N • 6/09

General Information
The EVD-2, Electronic Vibration Detector System, is listed by Underwriters Laboratories, Inc. and Underwriters Laboratories of Canada for
primary protection of Mercantile or Bank, safe or vault and supplementary protection of interior units such as fi le cabinets, display cases, walls
and ceilings. The System must be used with an appropriate UL listed control unit.
The standard EVD-2 system consists of a model EVD-M controller and a model EVD-R remote pickup.

Features
• Detects all common threats to safes, vaults and ATM's
• Sophisticated signal processing provides unprecedented sensitivity without false alarms
• Expandable system allows up to 15 remote pickups, (Model EVD-R)
• Reliable, sensitive piezo sensor technology
• On board high security safe contact interface
• Integral, multi-color status LED
• Built in test circuit on both controller and remote pickups
• Remote test and annunciator capabilities
• Supervised microprocessor
• Independent tamper output
• On board test point facilitates installation and service
• Built-in accumulator

Specifi cations

Dimensions: (EVD-M and EVD-R)

5.10"H x 3.26"W x 1.20"D

(13,0cm H x 8,3cm W x 3,0cm D)

Weight: EVD-M 0.64 lbs. (0,29 kg)

EVD-R 0.62 lbs. (0,28 kg)

Enclosure:

Base:

Die-cast

aluminum

Cover: Stamped Steel, 22 Gauge

Power Input: 9.0 VDC to 16.0 VDC, 12 VDC Nominal

Maximum 0.1 V ripple

Typical Current: (Supply Voltage 12.0 VDC)

Normal Standby Condition: 34 mA

Alarm Condition:

33 mA

Tamper Condition:

41 mA

Each additional EVD-R Remote Pickup adds approx. 3 mA

With model RTA connected, add 10 mA in Tamper Condition and 10 mA in Alarm condition

Maximum Current: (Supply Voltage 16.0 VDC)

Normal Standby Condition: 36 mA

Alarm Condition:

33 mA

Tamper Condition:

43 mA

With model RTA connected, add 14 mA in Tamper Condition and 14 mA in Alarm condition

Contact Data: Alarm Relay: Form C, 2.0 Amps at 30 VDC

Tamper Contact: Form A, 2.0 Amps at 30 VDC

Optional Accessories: RTA Remote Test Annunciator

UL Listed High Security Cable

Required for UL safe complete installations

Ordering Information

Description Stock

No.

EVD-2 System

2020300

Consisting

Of:

1 EVD-M Controller

2020250

1 EVD-R Remote Pickup

2020260

EVD-2C Safe/Vault Pak

2020240

Includes:

1 HSC-1 High Security Door Contact

Optional

Equipment:

RTA

Remote

Test

Annunciator

2000073

High Security Cable (“B” Cable) 5210408

Note: If 12 VDC is not available from main burglar panel, the following power supply and transformer is recommended:

12 VDC Power Supply

2020310

16.5 VAC Transformer

2020320