Potter EVD-2 User Manual
Page 5
5
EVD-2 • 5401042 • REV N • 6/09
General Information
The EVD-2, Electronic Vibration Detector System, is listed by Underwriters Laboratories, Inc. and Underwriters Laboratories of Canada for
primary protection of Mercantile or Bank, safe or vault and supplementary protection of interior units such as fi le cabinets, display cases, walls
and ceilings. The System must be used with an appropriate UL listed control unit.
The standard EVD-2 system consists of a model EVD-M controller and a model EVD-R remote pickup.
Features
• Detects all common threats to safes, vaults and ATM's
• Sophisticated signal processing provides unprecedented sensitivity without false alarms
• Expandable system allows up to 15 remote pickups, (Model EVD-R)
• Reliable, sensitive piezo sensor technology
• On board high security safe contact interface
• Integral, multi-color status LED
• Built in test circuit on both controller and remote pickups
• Remote test and annunciator capabilities
• Supervised microprocessor
• Independent tamper output
• On board test point facilitates installation and service
• Built-in accumulator
Specifi cations
Dimensions: (EVD-M and EVD-R)
5.10"H x 3.26"W x 1.20"D
(13,0cm H x 8,3cm W x 3,0cm D)
Weight: EVD-M 0.64 lbs. (0,29 kg)
EVD-R 0.62 lbs. (0,28 kg)
Enclosure:
Base:
Die-cast
aluminum
Cover: Stamped Steel, 22 Gauge
Power Input: 9.0 VDC to 16.0 VDC, 12 VDC Nominal
Maximum 0.1 V ripple
Typical Current: (Supply Voltage 12.0 VDC)
Normal Standby Condition: 34 mA
Alarm Condition:
33 mA
Tamper Condition:
41 mA
Each additional EVD-R Remote Pickup adds approx. 3 mA
With model RTA connected, add 10 mA in Tamper Condition and 10 mA in Alarm condition
Maximum Current: (Supply Voltage 16.0 VDC)
Normal Standby Condition: 36 mA
Alarm Condition:
33 mA
Tamper Condition:
43 mA
With model RTA connected, add 14 mA in Tamper Condition and 14 mA in Alarm condition
Contact Data: Alarm Relay: Form C, 2.0 Amps at 30 VDC
Tamper Contact: Form A, 2.0 Amps at 30 VDC
Optional Accessories: RTA Remote Test Annunciator
UL Listed High Security Cable
Required for UL safe complete installations
Ordering Information
Description Stock
No.
EVD-2 System
2020300
Consisting
Of:
1 EVD-M Controller
2020250
1 EVD-R Remote Pickup
2020260
EVD-2C Safe/Vault Pak
2020240
Includes:
1 HSC-1 High Security Door Contact
Optional
Equipment:
RTA
Remote
Test
Annunciator
2000073
High Security Cable (“B” Cable) 5210408
Note: If 12 VDC is not available from main burglar panel, the following power supply and transformer is recommended:
12 VDC Power Supply
2020310
16.5 VAC Transformer
2020320