Operating instructions – Perfect Aire NP10000 User Manual
Page 7
OPERATING INSTRUCTIONS
- Press the "MODE" button until the "COOL"
indicator light comes on.
- Press the ADJUST buttons "
" or "
" to
select your desired room temperature. The
temperature can be set within a range of
62
O
F-88
O
F/17
O
C-30
O
C.
- Press the "FAN" button to choose the
fan speed.
- Press the "MODE" button until the "DRY"
indicator light comes on.
- Under this mode, you cannot select a fan speed
or adjust the temperature.
- Keep windows and doors closed for the best
dehumidifying effect.
- Remove exhaust hose. (See page 11.)
COOL operation
DRY operation
- Press the "MODE" button until the "FAN" indicator
light comes on.
- Press the "FAN" button to choose the fan speed.
The temperature cannot be adjusted.
- Remove exhaust hose. (See page 11.)
FAN operation
TIMER operation
If setting the timer when the unit is on:
First press the TIMER button; the TIMER OFF
indicator light illuminates. It indicates the Auto Stop
program is initiated. Press the TIMER button again;
the TIMER ON indicator light illuminates. It
indicates the Auto Start program is initiated.
If setting the timer when the unit is off:
First press the TIMER button; the TIMER ON
indicator light illuminates. It indicates the Auto Start
program is initiated. Press the TIMER button again;
the TIMER OFF indicator light illuminates. It
indicates the Auto Stop program is initiated.
- Press or hold the UP or DOWN button to change
the Auto time by 0.5 hour increments, up to 10
hours, then at 1 hour increments up to 24 hours.
The control will count down the time remaining
until start.
- The selected time will register in 5 seconds and
the system will automatically revert back to
displaying the previous temperature setting.
- Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel the
Auto Start/Stop timed program.
- When the malfunction (E1 or E2) occurs, the Auto
Start/Stop timed program will also be cancelled.
E1- Room temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call customer service.
E2- Evaporator temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call customer service.
E4- Display panel communication error-
Unplug the unit and plug it back in.
If error repeats, call customer service.
P1- Bottom tray is full - Connect the
drain hose and drain the collected
water away. If error repeats, call
customer service.
Error and protection codes:
AUTO operation
- When you set the air conditioner in AUTO mode,
it will automatically select cooling or fan only
operation depending on the temperature you have
selected and the room temperature.
- The air conditioner will control room temperature
automatically around the temperature point you
have set.
- Under AUTO mode, you cannot select the
fan speed.
NOTE: When more than one error occurs,
the priority of the code display order is:
E4--E2--E1--P1.
SLEEP operation
In this mode the selected temperature will
increase by 2
O
F/1
O
C 30 minutes after the mode
is selected.The temperature will then increase
by another 2
O
F/1
O
C after an additional 30
minutes. This new temperature will be
maintained for 7 hours before it returns to the
originally selected temperature. This ends the
Sleep mode and the unit will continue to operate
as originally programmed.
NOTE: This feature is not available under FAN or
DRY mode.
6