CH and CL Series Power Amplifiers
Operation Manual
CL2
LOAD
Duty
Cycle
Current Draw(Amps)
Thermal Dissipation
Thermal Dissipation
Thermal Dissipation
Current Draw(Amps)
Current Draw(Amps)
AC Mains
Power
Draw
(Watts)
AC Mains
Power
Draw
(Watts)
AC Mains
Power
Draw
(Watts)
100-120 230-240 btu/hr kcal/hr
100-120 230-240 btu/hr kcal/hr
100-120 230-240 btu/hr kcal/hr
50%
40%
30%
20%
10%
8 OHMS DUAL / 16 OHMS BRIDGE
4 OHMS DUAL / 8 OHMS BRIDGE
296
1419
5.4
10.8
1075
260
1175
4.4
8.8
872
235
993
3.4
6.7
669
174
690
2.4
4.7
466
113
448
1.3
2.6
263
237
2 OHMS DUAL / 4 OHMS BRIDGE
142
563
1.8
3.6
360
232
922
3.3
6.6
660
323
1281
4.8
9.6
960
413
1639
6.3
12.6
1260
504
1998
7.8
15.6
1560
940
3.4
6.7
675
200
793
2.8
5.5
552
163
646
2.2
4.3
429
126
499
1.6
3.1
306
89
352
1.4
1.8
183
8 AC Power Draw and
Thermal Dissipation
Figure 8.5 Model CL2 Power Draw, Current Draw and Thermal Dissipation at Various Duty Cycles
Figure 8.6 Model CL4 Power Draw, Current Draw and Thermal Dissipation at Various Duty Cycles