beautypg.com

Interfaces, Serial interface, Serial interface (p.52) – Citizen Systems CLP-621 User Manual

Page 52: Appendixes

background image

Appendixes

52

Interfaces

This printer is connected to a computer and prints according to commands
sent from the computer.
There are three types of computer interfaces, and these are connected to
devices suited to each type of interface. The printer can also be connected
to a computer by the optional Ethernet and wireless LAN.

System

Start/stop asynchronous duplex communication

Signal level

RS-232C

Baud rate

2400, 4800, 9600, 19200, 38400,57600, 115200bps

Bit length

7Bit, 8Bit

Stop bit

1Bit, 2Bit

Parity

Odd, even, none

Connector

D-SUB 25PIN

Serial Interface

Specifications

Pin No. Signal code

Signal name

Function

1

FG

Protective

Protective grounding

grounding

2

TXD

Transmitted data

Signal line that transmits data from the
printer to other devices

3RXD

Received data

Signal line that transmits data from other
devices to the printer

4

RTS

Transmission

Pull up to +12V through 3.3k

request

5

NC

------

Not used

6

DSR

Data set relay

Signal line that is active when an external
device can interface with the printer

7

SGND

Signal line

Shows the ground level of the signal line

ground

8-13NC

------

Not used

14

VCC

+5V

(FACTRY USE ONLY )

15-19

NC

------

Not used

20

DTR

Data terminal

Signal line that is active when an external

relay

device can interface with the printer

21-25

NC

------

Not used

Signal line and pin arrangement