beautypg.com

Menu setting table (1/2), Printer operation, 36 menu setting table – Citizen Systems CLP-621 User Manual

Page 36: Menu setting mode settings

background image

2

Printer Operation

36

Menu Setting Table

Page Setup Menu - allows you to change settings related to the media or print quality.

System Setup Menu - allows you to change settings for the printer hardware and basic control systems.

After Print Menu - changes how the printer reacts after the label has been printed.

Interfaces - changes interface parameters such as baud rate.

Top Menu

Sub Menu

Default

Menu

Remarks

Page Setup

Print Speed

4 IPS

2 to 4 IPS

Printing speed setting

Print Darkness

10

00 to 30

Print darkness setting (printhead
temperature)

Darkness adjust

0

-10 to 10

Darkness command adjustment

Print method

Thermal transfer Thermal transfer

Selecting thermal transfer (ribbon)

Direct thermal

/direct thermal media

Continuous Media

4.00 IN

0.25 to 32.00 IN

Setting default length of continuous

Length

101.6mm

6.40 to 812.8mm

media, if selected. ; the lower line is in metric
mode.

Vertical Position

0.00 IN

-1.00 to 1.00 IN

Print start position adjustment

0.0mm

-25.4 to 25.4mm

Horizontal Shift

0.00 IN

-1.00 to 1.00 IN

Horizontal printing location adjustment

0.0mm

-25.4 to 25.4mm

Media Sensor

See Through

See Through

Label sensor selection

Reflect
None

Small Media

OFF

ON

Setting for small labels

Adjustment

OFF

Small Media

1.00 IN

0.25 to 1.00 IN

Setting length of small label media

Length

25.4mm

6.40 to 25.4mm

System Setup

Sensor Level

1.5V

0.0V to 3.3V

Setting the threshold of the sensor

Buzzer Select

ON

ON

Setting buzzer sounding conditions

OFF

Metric/Inch

Inch

Inch

Setting the units used

mm

Max Media Length

10.00 IN

1.00 to 50.00 IN

Setting the maximum label length

254.0mm

25.4 to 1270.0mm

Settings Lock

Off

On/Off

When on, prevents software commands from
changing the values set by the VuePrint menu

Keyboard Lock

Off

On/Off

Prevents the control panel from affecting
the printer's conrfiguration. (User "lock-out")

Control Code

STD

STD/ALT

Selects between the Standard STX control
code or the "Alternative" code. Sometimes
called "AS400 mode".

Emulation Select

DM4

DMI

Datamax compatibility selection

DM4

DMI DataMax IClass

DPP

DM4 DataMax 400 like
DPP DataMax Prodigy Plus

After Print

AutoConfigure

On

On

Optional auto configure

Off

On .... Auto configure effective.

If a peeler unit or auto-cutter is
installed, each mode is automatically
set regardless of the “function select”
setting.

Menu Setting

Mode Settings