beautypg.com

Menu setting table (2/2), 37 printer operation, Mode settings – Citizen Systems CLP-621 User Manual

Page 37

background image

37

Printer Operation

Top Menu

Sub Menu

Default

Menu

Remarks

Off ... Auto configure ineffective.

When a peeler unit or auto-cutter is
installed but has not been started, it is
off and the operation is selected by
“Function select”.

Function Select

Tear

Off

Selects the type of options installed and

Tear

adjusts the "paper stop" position accordingly.

Peel On*

For example, the position where the label

Cut On*

stops in "Tear" mode is different to that in
"Peel On" mode.

Cutter Action*

Backfeed

Backfeed

Cutter operating method setting

Through

Backfeed: it feeds back after each cutting
operation.
Through: when the number copied = n, the
back end of sheet 1 to n-1 passes through,
and the back end of the final page that is a
single sheet is copied and fed back.

Paper Position

0.00IN

Peel/Cut/Tear Off

T he stop position can be fine tuned using

0.00mm

0.00 to 2.00 IN

this menu setting. The general stop position

0.0 to 50.8mm

is selected depending on the "Function"

Peel/Cut/Tear On

selected above.

-1.00 to 1.00 IN
-25.4 to 25.4mm

Mode/Repeat Key

Disabled

LabelSet

Repeat method selection

LastOne

LabelSet:

Disabled

Reissues multiple labels.

LastOne:

Issues only the final page.
In count case, it issues only 1 label while
continuing.

Disabled:

Makes the repeat key invalid.

Interfaces

RS-232C Baud

9600

115200

Sets the baud rate of the serial interface.

57600

• Interface related settings are effective

38400

after the power is turned on again.

19200
9600
4800
2400

RS-232C Parity

None

None

Sets the communication parity of the serial

Odd

interface.

Even

RS-232C Length

8 bits

8 bits

Sets the character length of the serial

7 bits

interface.

RS-232C Stop bit

1 bit

1 bit

Sets the stop bit of the serial interface.

2 bits

RS-232C X-ON

Yes

Yes

Selects the X-ON flow control of the serial

No

interface.

IEEE1284

ON

ON

Enable or disables the 'enhanced' features of

OFF

the IEEE1284 parallel interface.

Mode Settings