COM-2(PC)F

55

Sample Program 11
[Data transmission and reception (COM3, COM4 mode)]

Sample program 11 uses the bios_serialcom( ) function for MS-C.
It first receives the data transmitted from COM3, and then receives
the data at COM3 transmitted from COM4. Received data is
displayed on the CRT.

1

COM3

Initialization

1

COM4

Initialization

Transmit 1-byte

Data from COM3

START

END

No

Yes

No

COM4 status check

ready to receive?

Yes

COM3

Initialization

COM4

Initialization

Transmit 1-byte

Data from COM4

No

Yes

COM3

Data Reception

No

Yes

COM4

Data Reception

Data reception A to K

from COM3 completed?

COM3 status check

ready to receive?

Data reception a to k

from COM4 completed?

Figure 6.13. Flowchart of Sample Program 11