beautypg.com

Т³гж 12 – OmniSistem Beta 3 – EC-2600U User Manual

Page 12

background image

|< >|

10

3). 3-band PEQ

4). Channel Level

5). Peak Limiter.

6). DELAY

7). Phase

8). Muting

9). Domain of output channel link

It offers 3-band PEQ for each output channel.

Each parameter of 3-band PEQ is same as the PEQ of master channel processing block.

Adjustable in 0.5dB steps over a range of oo -- +12.0dB.

Include Instantaneous waveform transformation type peak limiter in each channel. It can be set over a range

of -24.0dBFs+2dBFs, OFF at 0.5dB steps. When signal reaches the limiting level, the limiter indicator is lit.

Following is the chart before processing (narrow line) and after processing (wide line).

Real line: before processing Broken line: after processing

Capable adjust with 15.515

sec steps at 0- 2.034seconds ( 15.515 sec is equivalent to approximately

5.275mm in the speed of sound.

NOTE:

The minimum delay time between input and output while using an analog input/output is about 1.2msend

when delay time is set at 0. This delay is caused by signal's passing through A/D, D/A converter and the

signal processor.

Capable of switching normal or inverse (180

).

Capable of setting for each channel.

Except Muting and source of invoice is individual setting everlasting, Parameter of other channels can be

adjustable by link.

DIGITAL SPEAKER PROCESSOR