beautypg.com

Cleaning and maintenance – OmniSistem OnyxPro 75 User Manual

Page 16

background image

unit off. (Activates after 
5 minutes.) 

 

Adju 

CHXX=XXX 

Adjust Value of Each 
Channel 

Info 

DriT 

XXXC 

Driver Temperature 

Set 

Rest 

Rest 

Reset 

 

Move 

RPan                ON/OFF 
RTilt                  ON/OFF 
Degr                 630/540 
Enco                 ON/OFF 
Mode                Mod1/Mod2 

Reverse Pan 
Reverse Tilt 
Choose Pan Degree 
Encoder Wheel 
Choose Pan/Tilt Mode 

 

UI 

Mic                    0~99%, 60% 
Sign                  Close/Hold/Auto/Music 
Fan                   Auto Speed/High Speed 
Hibe                  OFF, 01M~99M, 15M 
Back                 02~60M, 02M 
Flip                   ON/OFF 
User                  Use1/Use2 

Mic Sensitivity 
Signal Mode 
Fan Mode 
Hibernate Time 
Backlight Time 
Flip Display 180° 
DMX Mode (St/Ex) 

 

Cali 

Code                 XXX 
CHXX                 XXX 

Password (050) 
Calibrate Channel 

 

Ver 

X1.0.0 

IC Version 

 

load 

ON/OFF 

Reload Default 

 

 
CLEANING AND MAINTENANCE
 

The operator needs to make sure that safety­related and machine­technical installations are inspected by an 
expert after every four years in the course of an acceptance test. 

 

The operator needs to make sure that safety­relating and machine­technical installations are inspected by a 
skilled person once a year. 

 

The following points must be considered during the inspection: 
1) All screws used for installing the devices or parts need to be tightly connected and not corroded. 
2) There must not be any deformations on housings, fixations, and installation spots (ceiling, suspension, 

trussing). 

3) Mechanically moving parts like axles must not show any traces of wearing (e.g. material abrading or 

damages) and must not rotate unbalanced. 

4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables), or 

sediments. Further instructions depending on the installation spot and usage need to be adhered by a skilled 
installer and any safety problems have to be removed. 

 

 

We recommend a frequent cleaning of the device. Please use a moist, lint­free cloth. Never use alcohol or 
solvents! 

16 of 18