beautypg.com

7 electrical installation – NORAC 5467BC-4B-JD10 User Manual

Page 19

background image



16

7 Electrical Installation

1. Locate the valve module installed on the NORAC valve block. Remove the plugs installed

in positions 7 and 8.

2. Connect the 2 pin connector on cables C10 into positions 7 and 8 on the valve module.

Connect the other end of cables C10 to the 2 pin connectors on the NORAC expansion
block (V02).

3. Disconnect and remove the two NORAC roll sensors (small rectangular box with a cable

running from it). See Figure 14 for locations.

Figure 14: Roll Sensor Locations

4. Connect the active roll sensor (E05) to the 8-way coupler (E11) where one of the roll

sensors was connected using cable C03 and a 2-way coupler (E12). Plug the unused
connector where the second roll sensor was connected using the 6-pin plug.