13

6.4 Wing Sensor Installation

1. The sensor brackets should be oriented forward (ahead of the boom).

2. The inner wing sensor mounting brackets (B20) are the two brackets with the shorter

mounting flange.

3. Mount the inner wing sensors approximately half-way between the chassis and the outer

wing sensors.

4. Mount the NORAC UC5 ultrasonic sensor into the sensor bracket and run the sensor

cable either through hole in the back or through the side cut-out and behind the bracket.
Ensure the cable is clear of moving parts and will not be damaged during folding.

Figure 8: Inner Wing Sensor Bracket Mounting Example

Front