9 Connecting the Sensors to the CANbus

1. Fasten the 8-way coupler (E11) to the boom with cable ties.

2. Connect cable C05 from the input module to the 8-way coupler.

3. Connect the boom frame roll sensor to the 8-way coupler. Connect the chassis roll sensor

to the 3-way coupler between cables C03 and C09.

4. Connect the main lift sensor to the 8-way coupler using cable C06 and a 2-way coupler

(E12). Cable C06 and item E12 may not be needed if the 8-way coupler is mounted close
enough to the main lift sensor.

5. Connect two cables (C07) to the 8-way coupler and route along the booms. Attach a 3-

way coupler (E10) to the boom where the cable ends. Plug the CANbus cable into the 3-
way coupler. Connect cable C08 to the 3-way coupler and route along the boom to the
outer wing sensors. Insert a plug (P03) into the unused connector on each 3-way coupler.
Follow existing cables and hoses to be sure the cable will not be pinched or stretched.

Figure 21: UC5 Module Locations and Cable Connections

6. At the sensor brackets, attach a 2-way coupler with terminator (E20) to the sprayer boom.

The 2-way coupler with terminator is the white two way coupler. Plug the sensor and the

CANbus cable into the 2-way coupler.

7. Insert the remaining 6-pin plugs (P03) into the unused connectors on the 8-way coupler.