beautypg.com

9 hydraulic installation, 1 valve block assembly – NORAC UC5-BC-HG06 User Manual

Page 23

background image



20

9 Hydraulic Installation

Ensure all pressure has been bled from the system before disconnecting any lines
or fittings. Hydraulic pressure will exist on the wing tilt circuits unless the wings
are being supported by other means. The hydraulic installation may be performed
with the wings in transport position, resting on the ground or with the tilt cylinders
fully extended.

Component failure due to oil contamination is not covered under the NORAC UC5
system warranty. It is recommended that a qualified technician perform the
hydraulic installation.

9.1

Valve Block Assembly

1. On a clean surface remove the plastic plugs from the block.

2. Mount the NORAC valve block to the sprayer near the Hagie valve block on the bottom

rail.

3. When plumbing the system, the “B” lines of the NORAC valve block must be connected to

the Hagie “raise” lines.

4. The “A” lines of the NORAC valve block must be connected to the Hagie “lower” lines.

Figure 19: Valve Block