4. Connect one of the valve module CANbus connectors to the existing cable labeled

“NORAC” running to the rear of the sprayer from the electrical box. Route cable C01
from the other CANbus connector to the 8-way coupler (E11).

5. With the valve module securely mounted to the valve block, connect the valve cables (C10),

to the valve coils.

6. If locking valves are not installed on the accumulators, install H20 and H21 onto the

accumulators.

7. Connect cable C11 from the valve module channel 5 connector to the left boom

accumulator shutoff valve.

8. Connect cable C11 from the valve module channel 6 connector to the right boom

accumulator shutoff valve.

Figure 25: Boom Accumulator Shutoff Valve

9. Insert the 2-pin plugs (P01) into the unused 2-pin connectors on the valve module.

10. Connect the temperature probe to the valve block using the supplied 3/8” x 1/2” hex bolt.

Figure 26: Valve Module - Valve Coil Connections

Pressure Port

Tank Port

Left Tilt Ports

Right Tilt Ports