beautypg.com

2 valve module – NORAC UC5-BC-RG13 User Manual

Page 22

background image



20

8.2 Valve Module

1. Install the valve module (E02) to the top of the NORAC valve block. Orient the 6-pin

Deutsch (CANbus) connectors towards the “P” and “T” ports with the label facing up.

Figure 22: Valve Module

2. Verify the valve coil connectors are oriented vertically (Figure 23).

Figure 23: Align Coils

3. Place the valve module between the valve coils. Slide a valve mounting bracket over the

connectors of the valve module and the valve coil connectors. This may require flexing the
plastic bracket slightly (Figure 24). Ensure the bracket is pushed over the connectors far
enough to allow the clips to engage behind the valve connectors.

Figure 24: Valve Module Bracket Installation

Output Number Normal Function

1

Left Up

2

Left Down

3

Right Up

4

Right Down

5

Left Accumulator

6

Right Accumulator

7

Option 3

8

Option 4