3 input module – NORAC UC5-BC-GV01 User Manual
Page 23
20
8.3 Input Module
1. Install the input module (E03) on the sprayer near the NORAC valve block. Secure it to
the boom using cable ties or optional brackets.
2. Connect the free end of the CANbus cable (C02) from the valve module to the input
module.
3. Insert the 12 pin plug (P02) into the OEM 3 connector on the end of the input module.
4. Connect the 12 pin connector on the tilt interface cable (C20) to the Thru 2 connector on
the side of the input module.
5. Insert the connectors on the other end of C20 into the tilt connectors on the GVM
solenoids.
Figure 22: Input Module Connections
6. Connect the 12 pin connector on the main lift interface cable (C21) to the Thru 1
connector on the side of the input module.
7. Insert the connectors on the other end of C21 into the main lift connectors on the GVM
solenoids.
8. If the sprayer has a bypass valve, insert the 2-pin tee connector marked “AUX 1” into the
bypass valve connection. If the sprayer does not have a bypass valve, connect the plug and
receptacle “Aux 1” connectors together.
9. Connect the male and female “Aux 2” connectors together.