15
7.2 Roll Sensor Mounting Guidelines: Center Pivot Booms
1. When mounting the roll sensors, mount one to the boom frame – lowest serial number,
one to boom carrier frame (intermediate frame - non-pivoting portion of the sprayer) and
one to the chassis (reference frame) – highest serial number. For optimal performance,
minimize the distance from the boom frame roll sensor to the pivot point (A) and minimize
the vertical distance between the intermediate frame roll sensor and the pivot point (B).
Figure 13: Roll Sensor Mounting on a Center Pivot Suspended Boom
2. Ensure the roll sensors are relatively level when the sprayer boom and chassis are level.
3. All roll sensor cables should be pointing towards the right hand wing of the sprayer when
looking from the rear of the sprayer.
4. The intermediate frame roll sensor can also be mounted inverted to minimize the distance
between the roll sensors (Figure 14).
Figure 14: Inverted Chassis Roll Sensor Mounting on a Center Pivot Suspended Boom
Connectors towards
Right-hand Wing