beautypg.com

8 module installation, 1 control module – NORAC UC5-BC-GV01 User Manual

Page 20

background image



17

8 Module Installation

An optional module mounting bracket kit is available for purchase from NORAC. The
mounting brackets are compatible with control modules and input modules. One kit is needed
per module.

Item

Part Number

Name

Quantity

B20

43708

UC5 MOUNTING BRACKET KIT (CONTROL AND INPUT MODULES)

1

8.1 Control Module

1. Refer to Figure 1 and Figure 17.

2. Securely mount the control module (E01) inside the sprayer cab using screws, cable ties or

optional brackets.

3. Connect the display terminal to the control module using the existing display cable. This

cable must be connected to the end of the control module with only one Deutsch
connector.

4. Connect the power cable (C30) to one of the two CANbus connectors on the control

module. Connect the other end of the power cable to an appropriate power source.

5. Route cable C01 from the other CANbus connector towards the rear of the sprayer.

6. At the spray system disconnect point there will be multiple connectors for the sprayer

electronics. At this point install the two way coupler (E12).

7. Connect cable C01 from the control module to the two way coupler.

8. Connect the second cable C01 to the two way coupler and route the cable to the rear of

the sprayer.

Figure 17: Control Module Mounting