7.2 Roll Sensor Mounting Guidelines: Trapeze-Suspended Booms

1. When mounting the roll sensors, mount the lowest serial number on the trapeze link

(boom frame) and the highest serial number on the trapeze support (chassis). For optimal

performance, minimize the distance from the boom frame roll sensor to the pivot point (A)
and minimize the vertical distance between the chassis roll sensor and the pivot point (B).

Figure 18: Roll Sensor Mounting on a Trapeze Suspended Boom

2. Ensure the roll sensors are relatively level when the sprayer boom and chassis are level.

3. Both roll sensor cables should be pointing towards the right hand wing of the sprayer.

4. Ensure both roll sensors are mounted adequately and that the cables provide enough slack

to allow sufficient boom roll.