beautypg.com

4 hydraulic installation, 1 valve mounting – NORAC UC4+BC+HG4 User Manual

Page 15

background image

12

4.4 H

YDRAULIC

I

NSTALLATION

WARNING!

The hydraulic system creates very
high pressure. Before disconnecting
any hydraulic lines ensure all pressure
has been bled from the system.

When changing the boom hydraulic
hoses leave the booms in
TRANSPORT POSITION.

4.4.1 Valve Mounting

1. On a clean surface remove all plastic

plugs from the NORAC hydraulic Valve

(V01) (Figure 13).

Figure 13: NORAC Valve Block

4. Insert the 0.047” orifice (F08) into the

“A” port of the 3rd station block with
the notch facing in (Figure 14).

5. Insert the 0.042” orifice (F09) into the

“B” port of the 3rd station block with
the notch facing in (Figure 14).

Figure 14: Orifice Orientation

2. Mount the NORAC valve block to the

sprayer’s valve mounting bracket, as
shown in Figure 15.

Figure 15: NORAC Valve Block

Mounting Location

For the remainder of the hydraulic
plumbing, refer to Figure 3.