1. Connect the 6-pin tower on the valve cable

(C03) to the mating 6-pin shroud (S6A) on
C11.

2. Install the 2-pin connectors from C03 onto

the NORAC valve block ().

3. Connect the 3-pin tower on cable C15 to

the mating 3-pin shroud on cable C14.

4. Install the 2-pin connectors from C15 onto

the NORAC expansion block with the

connector labeled ROLL CW on the same
side of the block as the UP connectors from
C03.

5. The connectors on the valve cable (C03)

are marked RIGHT UP, LEFT UP,
RIGHT DOWN and LEFT DOWN.
Cables labeled with UP go on the same side

as the hydraulic hoses.

Figure 20: C03 and C15 Connections

6. Connect the CAN Node cable (C02B) to P4

on the valve extension cable (C11).

7. Route the CAN Node cable (C02B) to the

roll sensor and the ultrasound sensor
installed on the linear roll cylinder. Follow
existing cables and/or hydraulic lines.

8. Connect the 4-pin AMP connectors on

C02B to the sensors.

9. Connect the sensor branch cable (C02) to

the 4-pin AMP plug on C02B.

10. Route the sensor branch cable (C02) to the

wing and main sensors and connect to the
sensors. Follow existing cables and/or
hydraulic lines along the boom

11. Gather up excess cable (C11, C02) and

neatly cable-tie to the machine.