11

4.4 H

YDRAULIC

I

NSTALLATION

WARNING!

The hydraulic system creates very high
pressure. Before disconnecting any
hydraulic lines ensure all pressure has
been bled from the system.

IMPORTANT:

Component failure due to oil
contamination is not covered under the
UC4+ Spray Height Control system
warranty. It is recommended that a
qualified technician does the hydraulic
installation.

4.4.1 Expansion Block Assembly

This is only applicable if using a

44963D and 44962D in place of

44960D.

1. Remove the four 4MBP plugs from the 2-

station valve block.

2. Coat the four o-rings in hydraulic oil and

install them into the expansion block.

Ensure the o-rings are seated properly.

3. Attach the expansion block to the 2-station

block using the included spring washers and
bolts.

4. Tighten the bolts to 31 ft-lbs.